Lambda Bank 1 Closed Loop Control State🔗
Lambda bank 1 closed-loop control state as follows - 1. Close Loop Lambda - Enabled 2. Close Loop Lambda - Disabled 3. Close Loop Lambda - Active 4. Close Loop Lambda - Not Allowed - Enable Delay (user can vary the delay by tuning - Closed Loop Lambda Control Enable Delay table) 5. Close Loop Lambda - Not Allowed - After Start Enrich Active 6. Close Loop Lambda - Not Allowed - ECT Below Defined Threshold 7. Close Loop Lambda - Not Allowed - Sensor Faulted (If one sensor faults out, both banks use the good working sensor for correction. However, if both sensors fault out, the closed-loop operation stops) 8. Close Loop Lambda - Not Allowed - DFCO 9. Close Loop Lambda - Not Allowed - Injector Cut (Any limiter active or fuel cut/correction in-process) 10. Close Loop Lambda - Not Allowed - Sensor None Selected (both banks use the good working "selected" sensor for correction. However, if both sensors are none selected, the closed-loop operation stops) 11. Close Loop Lambda - Not Allowed - Sensor Not Fitted (both banks use the good working "fitted" sensor for correction. However, if both sensors are not fitted, the closed-loop operation stops) 12. Close Loop Lambda - Not Allowed - Sensor Not Ready 13. Close Loop Lambda - Not Allowed - TipOut