Lambda Reading Selection Mode

Lambda reading selection mode. Final lambda values for closed-loop control are decided by this parameter. The selection mode are as follows - 1. Respective Lambda Reading - Lambda sensor 1 & 2 readings will be used for bank 1 & bank 2 closed-loop correction calculation, respectively. 2. Average Lambda - The Average of both lambda sensors will be used for both bank 1 & bank 2 closed-loop correction calculation. 3. Lambda 1 Only - Lambda sensor 1 reading will be used for both bank 1 & bank 2 closed-loop correction calculation. 4. Lambda 2 Only - Lambda sensor 2 reading will be used for both bank 1 & bank 2 closed-loop correction calculation. 5. Leanest - The leanest of two lambda sensor readings will be used for both bank 1 & bank 2 closed-loop correction calculation. 6. Richest - The richest of two lambda sensor readings will be used for both bank 1 & bank 2 closed-loop correction calculation.