Manifold Absolute Pressure Hybrid Threshold Hysteresis🔗

In hybrid mode, this is the manifold absolute pressure that serves as a hysteresis (mode switch delay) between mass airflow mode and speed density mode.

A switch from the "upper" to the "lower" of these two modes may be triggered when manifold absolute pressure falls below the Manifold Abs Pressure Hybrid Threshold minus this value.

Higher values prevent frequent switching back and forth between modes when manifold absolute pressure remains near the threshold.

Range: 0 - 100 kPa

Note

  • The Hybrid Switch Mode parameter specifies which mode (MAF or speed density) is the "upper" mode and which is the "lower" mode.