Boost Control Integral Deadband🔗
If Boost Pressure Error is less than this value, it will be treated as zero error when updating the Boost Control Integral Term. (In other words, the Integral Term will not change this cycle because the error is effectively zero.)
This defines a range around the target boost pressure (Boost Pressure Setpoint) within which the integral term does not actively contribute to adjustments and has the effect of freezing the integral term when manifold relative pressure nears the target.
Range: 0 to 10 kPa