Skip to content

Over Boost Soft Limiter Integral Gain🔗

This table defines over boost soft limiter integral gain as a function of gear number index and over boost soft limiter manifold relative pressure error. The gain specified here specifies the overall magnitude of the integral term.

When calculating the integral term, this value is multiplied by the Over Boost Soft Limiter Manifold Relative Pressure Error, which is then multiplied by the time period between each calculation of the integral term. The resulting value is added to the integral term from the previous cycle.

Cell data range: 0 to 100 %/kPa/s