Idle Airflow Integral Deadband🔗

If the idle trajectory error is less than this amount of rpm, it will be treated as zero error when updating the Integral Term. (In other words, the Integral Term will not change this cycle because the error is effectively zero.)

Note

This does not reset the Integral Term to zero. The term merely remains at its current value.

Range: 0 to 1000 rpm