Nitrous Pressure (NOS) Sensor DTC Maximum Volts🔗
Specifies the maximum allowable voltage for the signal from the nitrous pressure sensor (open circuit threshold).
Typically, the voltage specified here serves as a threshold above which technicians should suspect that there is a problem with the nitrous pressure sensor or its wiring.
Note
Voltages above this threshold will set DTC P1348.