Soft Limiter Feed Forward (Map 1)🔗

This is one of four tables that specify soft limiter feed forward (%) as a function of gear number index. This table is used when Soft Limiter Map Select is set to 1.

The feed forward term is the portion of the total throttle position correction applied that is based on the current drive gear selected.

To fill out this table correctly:

  1. Ensure that Soft Limiter Threshold (Map #1) is configured to match the engine speed threshold that you want to use to activate the soft limiter.
  2. For each drive gear in the table:
    1. Run the engine in that gear.
    2. Apply throttle until you determine the amount of throttle (%) that you need to apply steadily to reach the soft limiter threshold.
    3. Enter this throttle % in the corresponding table cell.
  3. You should now have a good initial value for the feed forward term. Adjust as necessary to achieve optimum results.